CONTACT US

Our Address

Science Avenue, High-tech Zone, Zhengzhou City, Henan Province, China

  • Proper Piping for Vacuum Systems - graham-mfg

    design when vacuum equipment is placed in a building or an ele-vated structure. For example, consider an installation site with a highest recorded barometric pressure of 30 in. Hg. The plant has been laid out, and the most-economical placement of the vacuum vessel (assume a process precondenser) is at an elevation of 32 ft, next to the evaporator.

  • Vacuum Pump Separator/Silencers - VANEC

    Due to the vacuum condition, a secondary pump (barometric leg) may be required to drain the separator sump. If a barometric leg is utilized, the vertical length should be 13.6 inches for each inch of mercury (Hg) vacuum, the barometric leg should also have a liquid seal loop at the bottom.

  • Dewatering Vacuum Pumps For Paper Machinery Vooner

    Separators of vacuum process water, barometric drop legs and unloader pumps. Vooner inlet separators provide vacuum pump protection from process liquid carry-over. By removing the process liquids prior to the vacuum pump , erosion and corrosion is reduced and stable vacuum levels are maintained.To remove the separated white water from the ...

  • MT: Troubleshooting Low Vacuum Levels NASH

    Vacuum pre-separators operate with either a barometric seal leg (pipe) or with a low NPSH removal pump. The seal leg is the simplest design, but failure to correctly design, install, and operate this simple system will result in perpetual vacuum system problems, so a

  • Vacuum Separators Spencer Turbine

    Filtration Designs. We regularly supply filtration equipment to boost the capacity and efficiency of our vacuum systems. We employ only the most effective techniques such as two-stage separation. For instance, a tubular filter bag separator can be installed downstream from a centrifugal separation unit to trap over 99 percent of the remaining solids — including even difficult to capture ...

  • Air/Water Separator - Air Techniques

    Air/Water Separator Nitrous scavenging system for wet-ring vacuums. Water recycling system included in Hydromiser Air/Water Separator. ... Control your air, water and vacuum equipment using remote switches from your office. Details. Vacuum Systems. Vacuum Equalizer .

  • Vacuum Pump Silencers - Fluid Technology

    Vacuum Pump Liquid Separator-Silencers When a vacuum pump starts operating at normal atmospheric pressure, system pressure drop and power requirements are at their maximum. As the vacuum pump continues to evacuate the system, the inlet pressure decreases so the system pressure losses and power requirements decrease.

  • Calculator: Pipe Sizing by Pressure Loss for Air TLV - A ...

    TLV CORPORATION is a proud member of the Fluid Controls Institute (FCI), a non-profit association of fluid control equipment manufacturers. FCI has distinguished itself in the technical advancement of the fluid control industry through the development of standards to promote the production of higher quality, more useful products.

  • Products Flamco Group

    The Flamco Group is concerned with the development, production and sale of high-quality components for use in HVAC systems. In more than 70 countries, we offer successful, innovative solutions for problems including residential and commercial building and sustainable energy.

  • Chapter 3: Review of Basic Vacuum Calculations

    Vacuum: from a practical sense, vacuum may be defined as the condition of a gas under less than atmospheric pressure. Table 3.1: Vacuum ranges Vacuum Description Range Low vacuum 25 to 760 Torr Medium vacuum 10-3 to 25 Torr High vacuum 10-6 to 10-3 Torr Very high vacuum 10-9 to 10-6 Torr Ultrahigh vacuum 10-12 to 10-9 Torr

  • Air/Water Separator - Air Techniques

    Air/Water Separator Nitrous scavenging system for wet-ring vacuums. Water recycling system included in Hydromiser Air/Water Separator. ... Control your air, water and vacuum equipment using remote switches from your office. Details. Vacuum Systems. Vacuum Equalizer .

  • Vacuum Pump Silencers - Fluid Technology

    Vacuum Pump Liquid Separator-Silencers When a vacuum pump starts operating at normal atmospheric pressure, system pressure drop and power requirements are at their maximum. As the vacuum pump continues to evacuate the system, the inlet pressure decreases so the system pressure losses and power requirements decrease.

  • Contained Powder Transfer: Vacuum-Based Pneumatic ...

    Jun 12, 2015  The Vacuum Conveyor – represented by items 1, 2, 4, 5, and 6 in Figure 2, is the actual vacuum generator or pump, filter, separator, and conveying lines that form the means of transfer. The Product Unloading Point – or receiving vessel (item 7) is the place or machine at the discharge point of the conveyor, to which the material is ...

  • Products Flamco Group

    The Flamco Group is concerned with the development, production and sale of high-quality components for use in HVAC systems. In more than 70 countries, we offer successful, innovative solutions for problems including residential and commercial building and sustainable energy.

  • TEN MYTHS REVEALED ABOUT PAPER MACHINE VACUUM

    ATMOSPHERIC PRESSURE 30 252 20 506 10 0 20 10 5 0 0 10 11.3-5 22.6-15 34-10 40 1012 20 5 0 760 15 0 030 ... we don’t install a vacuum separator between the uhle boxes and vacuum pumps ... • No separator often results in larger pipe sizes and complicates piping runs

  • Condenser System Vacuum Equipment in Sugar Single Entry ...

    Condenser system and vacuum equipment are common to evaporators and vacuum pans. Nearly all these vessels use direct contact condensers, where the cooling water comes into direct contact with the vapour to be condensed.. Creation of Vacuum:. a) In a condenser, we condense large volume of vapour and it will only produce a comparatively small volume of water or (condensate) and this water runs ...

  • Barometric Leg - Technical Data Dekker Vacuum Technologies

    A barometric leg is basically a condensate drain. In a vacuum system that is used to condense steam and condensable vapors through heat exchangers or condensers, the condensate is normally dropped into a receiver tank that is often vented to atmosphere or a low-pressure vent system.

  • Diy Cyclonic Dirt Seperator From Pvc Bits and a Bucket : 5 ...

    5 gallon bucket with air tight lid these were about $4 make sure it has the rubber seal ring apiece of ply is good for supporting the lid for longevity 4" pvc had laying around 2"pvc ditto there was a cart of short pre cut pieces at my store so you didnt have to buy 10' sections 1 toilet floor mount adapter 4" 3" flat adapter 2" to 4" cone adapter 4" to link with 2" t 45 not 90 4" coupler 4 ...

  • Chapter 3: Review of Basic Vacuum Calculations

    Vacuum: from a practical sense, vacuum may be defined as the condition of a gas under less than atmospheric pressure. Table 3.1: Vacuum ranges Vacuum Description Range Low vacuum 25 to 760 Torr Medium vacuum 10-3 to 25 Torr High vacuum 10-6 to 10-3 Torr Very high vacuum 10-9 to 10-6 Torr Ultrahigh vacuum 10-12 to 10-9 Torr

  • Piping Symbol Legend - htproducts

    3. A minimum of 6 pipe diameters of straight pipe shall be installed upstream and downstream of all closely spaced tees. 4. The minimum pipe size for connecting a Super Stor water heater is 1 inch. 5. The minimum pipe size for connecting a Munchkin boiler shall be no smaller than the units connection size on supply return piping. 6.

  • Installation/User Guide Operation ... - - JUN-AIR

    The JUN-AIR vacuum suction system is designed to ... Exhaust vent pipe to outside 1.5 inch NPT (must be metal) Line from operatory See applicable plumbing diagram Inlet hose barb on vacuum separator tank 1.5 inches 1.5 inches 1.5 inches Separator tank drain

  • Nash XT Vacuum Pump intro and how it works - YouTube

    Nov 06, 2014  The vacuum pump draws the operating seal water from the separator tank through the air/water cooler. The ambient air cools the operating liquid before it enters the vacuum pump. The water is

  • Where should an air separator be located? Caleffi

    Jun 15, 2015  Remember, an air separator is a multi-pass device and over time it will "scrub out" air and can bring the dissolved air content down to less than 0.5% of system volume. In that condition, the water will provide excellent heat transfer (air is an insulator, not a good conductor), and virtually eliminate noise (air makes noise in a hydronic system).

  • Industrial Central Vacuum System Hoffman Lamson

    Changes to United States Occupational Health Regulations Call for Vacuum Technology from Hoffman Lamson. HOFFMAN LAMSON’s engineered vacuum systems have provided important support in safeguarding our customer’s most valuable assets – their employees – from a potential workplace hazard, as well as helping our customers bring their processes in compliance with updated U.S ...

  • TEN MYTHS REVEALED ABOUT PAPER MACHINE VACUUM

    ATMOSPHERIC PRESSURE 30 252 20 506 10 0 20 10 5 0 0 10 11.3-5 22.6-15 34-10 40 1012 20 5 0 760 15 0 030 ... we don’t install a vacuum separator between the uhle boxes and vacuum pumps ... • No separator often results in larger pipe sizes and complicates piping runs

  • Drain Separator for Vacuum

    Air piping should be thoroughly flushed before mounting. 2. When piping and fittings, etc. are being screwed together, be certain that cutting chips from the pipe threads, sealing material, and other debris do not get inside the piping. Further, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the pipe. 3.

  • Nash XT Vacuum Pump intro and how it works - YouTube

    Nov 06, 2014  The vacuum pump draws the operating seal water from the separator tank through the air/water cooler. The ambient air cools the operating liquid before it enters the vacuum pump. The water is

  • Barometric Leg - Technical Data Dekker Vacuum Technologies

    A barometric leg is basically a condensate drain. In a vacuum system that is used to condense steam and condensable vapors through heat exchangers or condensers, the condensate is normally dropped into a receiver tank that is often vented to atmosphere or a low-pressure vent system.

  • Condenser System Vacuum Equipment in Sugar Single Entry ...

    Condenser system and vacuum equipment are common to evaporators and vacuum pans. Nearly all these vessels use direct contact condensers, where the cooling water comes into direct contact with the vapour to be condensed.. Creation of Vacuum:. a) In a condenser, we condense large volume of vapour and it will only produce a comparatively small volume of water or (condensate) and this water runs ...

  • Installation/User Guide Operation ... - - JUN-AIR

    The JUN-AIR vacuum suction system is designed to ... Exhaust vent pipe to outside 1.5 inch NPT (must be metal) Line from operatory See applicable plumbing diagram Inlet hose barb on vacuum separator tank 1.5 inches 1.5 inches 1.5 inches Separator tank drain

  • Filters McMaster-Carr

    McMaster-Carr is the complete source for your plant with over 595,000 products. 98% of products ordered ship from stock and deliver same or next day.

  • PRE-INSTALLATION GUIDE for DENTAL VACUUM SYSTEMS

    40 pipe WARNING: Condensation of Water will occur in vent piping. Avoid Accumulation of water in vent. Slope pip-ing toward separator. Note: See Optional Drain Connections Typical for both VacStar VS20 and VS40 View B. VacStar with Wall-Mounted Air/Water Separator Building Power Supply Panel (Should be located in equipment room.) Buck/Boost ...

  • BASIC HYDRONIC SYSTEM DESIGN - ASHRAE

    HYDRAULIC SEPARATORS Increasing pipe size reduces velocity and creates area of very low pressure drop Hydraulic Separator with air/dirt media Hydraulic Separator “BUFFER” TANKS Purpose: increase the amount of fluid in a system to prevent the short cycling of chillers, boilers, etc. Buffer Tank Two connections – Volume Multi-Purpose Tank

  • Where should an air separator be located? Caleffi

    Jun 15, 2015  Remember, an air separator is a multi-pass device and over time it will "scrub out" air and can bring the dissolved air content down to less than 0.5% of system volume. In that condition, the water will provide excellent heat transfer (air is an insulator, not a good conductor), and virtually eliminate noise (air makes noise in a hydronic system).

  • air separator CALEFFI

    The DISCAL® air separator is used to continuously remove the air contained in hydronic circuits of heating and cooling systems. The air discharge capacity is very high. They automatically remove all the air present in the system down to micro-bubble level with low head loss due to the special internal shape of the separator body. Flow direction

  • Drain Separator for Vacuum - Steven Engineering

    Drain Separator for Vacuum 1263 Removes water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Cleaning water Pad Ejector OUT side IN side Drain separator for vacuum 2 port solenoid valve Drain ZA ZX ZR ZM ZMA ZQ ZH ZU ZL ZY ZF ZP SP ZCUK AMJ AMV AEP HEP Related Equipment 4-5-28-AMJ.qxd 09.9 ...

  • Chilled Water Systems - Back to Basics Jonathan Ramajoo ...

    Oct 17, 2012  Vacuum Breakers copper there is a risk of pipe implosion if a cooling tower isolation valve is shut while the pump is running. • To prevent this occurring, a vacuum breaker is required. This takes the form of a standing pipe in the pump suction line which will allow air to enter the system andallow air to enter the system and

  • Installation and Operating Guide

    Syclone Amalgam Separator near your vacuum unit. Place in an easily accessible location for replacement of collection ... • Use a Phillips-head screwdriver to tighten the screws ... • Tilt the canister towards the outlet pipe to allow air into the top chamber. • Place the canister back on and insert the pins.

  • Filters McMaster-Carr

    McMaster-Carr is the complete source for your plant with over 595,000 products. 98% of products ordered ship from stock and deliver same or next day.

  • Cyclonic Separator Shop-Vac With Secondary Water ...

    This shop vac has 3 main parts, the cyclonic separator, the vacuum housing, and the wet scrubber. The Cyclonic Separator portion is made from a CD spindle case, a toy traffic cone, and some 1 1/4" PVC Pipe. I acquired the vacuum motor from another broken upright vacuum cleaner. I created a housing for the motor using scrap particle board.

  • US20090307866A1 - Shop Vacuum Cleaner with Cyclonic ...

    A shop vacuum cleaner has a series of dust separation stages, with the large majority of the dust being preseparated in a cyclonic separator and deposited into a first drum or barrel. The remaining dust that is carried in the air stream is filtered out in a pre-filter in a second vacuum cleaner drum. A final filter cartridge is fitted onto the intake of the vacuum head.

  • Installation and Operating Guide

    Syclone Amalgam Separator near your vacuum unit. Place in an easily accessible location for replacement of collection ... • Use a Phillips-head screwdriver to tighten the screws ... • Tilt the canister towards the outlet pipe to allow air into the top chamber. • Place the canister back on and insert the pins.

  • Flexible Hose for Dust Collection Oneida Air Systems

    Dust Collection Systems. For over two decades Oneida Air Systems has been renowned as the industry leader in dust collection - never compromising on performance or filtration - to ensure the safest and healthiest work environment for shop owners.

  • Air / Oil Separators: PSI Global - The natural choice

    Vacuum Separators PSI Global Vacuum Separators - The Benefits PSI Global supplies vacuum separators to many of the industry’s leading OEMs and through close collaboration with customers the company has become a market leader in the complex field of separation technology.. The company's vacuum oil-mist eliminators are the natural choice for overcoming inherent industry problems of

  • PRE-INSTALLATION GUIDE for DENTAL VACUUM SYSTEMS

    40 pipe WARNING: Condensation of Water will occur in vent piping. Avoid Accumulation of water in vent. Slope pip-ing toward separator. Note: See Optional Drain Connections Typical for both VacStar VS20 and VS40 View B. VacStar with Wall-Mounted Air/Water Separator Building Power Supply Panel (Should be located in equipment room.) Buck/Boost ...

  • Chilled Water Systems - Back to Basics Jonathan Ramajoo ...

    Oct 17, 2012  Vacuum Breakers copper there is a risk of pipe implosion if a cooling tower isolation valve is shut while the pump is running. • To prevent this occurring, a vacuum breaker is required. This takes the form of a standing pipe in the pump suction line which will allow air to enter the system andallow air to enter the system and

  • Section 22 62 19.74 - DENTAL VACUUM AND EVACUATION

    A.Pipe Leakage Test: Test in accordance with NFPA 99, 5.3.12.2.5 Category 3 Plastic Vacuum Piping Systems. Exhaust complete piping system to a vacuum of not less than 27 kPa (8 inch Hg) after the pipe line is dried out initially. Vacuum shall not decrease by more than 1.4 kPa (0.4 inch Hg) in one hour.

  • APCO AIR VALVE GUIDE - DeZURIK, Inc.

    2. Air/Vacuum Valves An Air/Vacuum Valve (AVV) is float operated, having a large discharge orifice equal in size to the valve inlet. This valve allows large volumes of air to be exhausted from or admitted into a system as it is filled or drained. Used on pipelines, the following conditions would prevail:

  • WTF is a Franzinator? - Blogger

    Pipe the same size the air compressor port will use, 16"-18" long.Some exhaust pipe, the same length as the other pipe.Some washers you have to make with a hole saw, enough to put one on each end and one every 1-1/2" that will fit around the air compressor intake port pipe and fit inside the exhaust pipe.Steel wool to fit between the washers.A

  • Pipe Vacuum Pressure Load Equations Formulas Design Calculator

    Pipe load calculator solving for vacuum load per linear length of pipe given internal vacuum pressure and inside pipe diameter

  • Solberg Filtration Filters, Silencers, Vacuum Filters ...

    Vacuum Process Filtration Separation. Inline inlet vacuum filter and discharge filter assemblies used on the inlet of vacuum pumps, blowers and compressors to capture particulate. Discharge Filters used on the exhaust side of the vacuum pump to capture oil mist, fog and aerosols.

  • Cyclone Separator for Shop Vacuum : 6 Steps (with Pictures ...

    Cyclone Separator for Shop Vacuum: My shop vac filter element was plugging up with dust much to frequently for my tastes. To reduce the dust loading to the filter, I built a cyclone separator to act a a prefilter to the shop vac. Materials: 2 - 5 gallon plastic buckets with lids...